Screen Wiring and Configuration
Screen Wiring
- TFT Resistive Screen Wiring
- C8 V1-V1.2 Using G2T Wiring
- C8 V1.3 Version
- HDMI Wiring
TFT Resistive Screen Wiring
tip
- The TFT screen package includes two FPC cables: one is
14P (narrow)
and the other is16P (wide)
- Please use the 14P (narrow) cable for resistive screens!!!
- FLY-C8 TFT resistive screen wiring
![]() |
|
TFT V2 Wiring
tip
- C8 V1-V1.2 does not support TFT V2 capacitive screen wiring and must be used with G2T
- The TFT screen package includes two FPC cables: one is
14P (narrow)
and the other is16P (wide)
- Please use the 16P (wide) cable for G2T screens with TFT V2!!!
- Install G2T and TFT screen
![]() |
![]() |
TFT V2 Wiring
tip
- The TFT screen package includes two FPC cables: one is
14P (narrow)
and the other is16P (wide)
- Please use the 16P (wide) cable for G2T screens with TFT V2!!!
- Install G2T and TFT screen
- Using TFT screen
Screen Configuration
- FLYOS-FAST System - Screen Configuration
- FLYOS-Armbian System - Screen Configuration
FLYOS-FAST System - Screen Configuration
-
Open the device IP address in the browser, for example:
http://192.168.6.110/
fluidd
as shown below:Uncheck
->Filter hidden files and folders
.mainsail
as shown below:Check
->Show hidden files
. -
You can now see the
.flyos-config
folder. Enter this folder to find thesys-config.conf
file.

- Open the
sys-config.conf
file, modify the required configuration items, thenSave
->Close
.
warning
HDMI screen
configuration:hdmi
. Please note that there must be no space after the = sign!!!Resistive screen
configuration:fly-tft-v1
orfly-tft-v2-r
. Please note that there must be no space after the = sign!!!. Please confirm the screen DIP switch is set toResi
Capacitive screen
configuration:fly-tft-v2-c
. Please note that there must be no space after the = sign!!!. Please confirm the screen DIP switch is set toCap
klipper_screen
configuration:1
. Please note that there must be no space after the = sign!!!- Note: The configuration format in the
sys-config.conf
file iskey=value
. Do not modify the format!!! Otherwise, the configuration will not take effect!!!

- After saving the changes,
restart the system
to take effect.
FLYOS-Armbian System - Screen Configuration
info
- Connect the host computer to WiFi and obtain its IP address. Enter
IP+:9999
in the browser to access FLY TOOLS for screen-related configuration. - For example, if your host computer's IP address is
192.168.6.110
, you need to enter192.168.6.110:9999
in the browser.
- Open FLY TOOLS. Follow the steps shown in the figure below to
Enable Klipper Screen
,Select screen model
, click the pink button in the lower right cornerSave Configuration
, and then restart the host computer to take effect!
warning
Resistive screen
selection:fly-tft-v1
orfly-tft-v2-r
. Please confirm the screen DIP switch is set toResi
Capacitive screen
selection:fly-tft-v2-c
. Please confirm the screen DIP switch is set toCap
HDMI screen
selection:hdmi
![]() |
![]() |
![]() |
- After saving the configuration, restart the host computer to take effect.
Loading...